Quality Control Solutions  

藉由逐漸在無影片的環境提供的診療,要求是給能提供更高可信度的顯視器,以"Optimum Image, Same Image"為主要訴求,EIZO 以它實際廣泛的經驗和可信度作為一個專業的顯示器製造商。這結果是產生了最原本的影像品質而且還能為吃不同顯示器之間依定的品質。

     
   

Quality control is vital for monitors.

顯示器的品質能保持不便嗎?

顯示的品質取決於亮度,灰階和亮度的均勻度會隨著時間而有些微的變化。

---------------------------------------------------------------------------------

當顯示器品值改變時會有什麼情況?

在醫院,在診斷時使用兩台以上不同的螢幕觀看同樣圖片時,在每個螢幕下的任何改變或是彼 此之間不同都會造成嚴重的問題。

---------------------------------------------------------------------------------

如何維持顯示器的品質?

顯示器的品質管理(QC)昰被要求作檢驗的和針對顯示器的 特性的些微改變來做校正,讓品質維持ㄧ致的穩定性。

---------------------------------------------------------------------------------

有那些是螢幕QC的標準?

■ AAPM TG18 “Assessment of Display Performance for Medical Systems”
A standard established by task group (TG) 18 of the American Association of Physicists in Medicine (AAPM).

■ DIN V 6868-57
“Image Quality Assurance in X-Ray Diagnosis - Part 57” established by the Deutsches Institut fur Normung e.V. (DIN). In line with the QS-RL (Qualitatssicherungs-Richtlinie) quality assurance ordinance, it is mandatory in Germany to refer to this standard when conducting monitor quality assurance.

■ PAS 1054
“Requirements and Testing of Digital Mammography Equipment” established by the Normenausschusses Radiologie (DIN NAR) in cooperation with the Deutschen Rontgengesellschaft (DRG) and others. In line with the QS-RL (Qualitatssicherungs-Richtlinie) quality assurance ordinance, it is mandatory in Germany to refer to this standard when conducting monitor quality assurance.

■ IEC 61223-2-5
“Evaluation and Routine Testing in Medical Imaging Departments - Part 2-5” established by the International Electrotechnical Commission (IEC).

■ IPEM Report 91
“Recommended Standards for the Routine Performance Testing of Diagnostic X-Ray Imaging Systems” established by the Institute of Physics and Engineering in Medicine (IPEM).

■ JESRA X-0093
“Quality Assurance (QA) Guideline for Medical Imaging Display Systems” established by the Japan Industries Association of Radiological Systems (JIRA) in 2005.

■ ACR “Practice Guideline for Determinants of Image Quality in Digital Mammography”
A standard established by the American College of Radiology (ACR) in cooperation with the American Association of Physicists in Medicine (AAPM), Radiological Society of North America (RSNA), and Society for Imaging Informatics in Medicine (SIIM).

■ EUREF “European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis”
A standard issued by the European Commission in cooperation with the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services (EUREF), and European Breast Cancer Network (EBCN), European Society of Mastology (EUSOMA).

---------------------------------------------------------------------------------

那些軟體可以來校正螢幕的QC?

您需要一套軟體然後根據螢幕的特性定期得來校正它,確保螢幕的品質。