Quality control is vital for monitors.
顯示器的品質能保持不便嗎?
顯示的品質取決於亮度,灰階和亮度的均勻度會隨著時間而有些微的變化。
---------------------------------------------------------------------------------
當顯示器品值改變時會有什麼情況?
在醫院,在診斷時使用兩台以上不同的螢幕觀看同樣圖片時,在每個螢幕下的任何改變或是彼 此之間不同都會造成嚴重的問題。
---------------------------------------------------------------------------------
如何維持顯示器的品質?
顯示器的品質管理(QC)昰被要求作檢驗的和針對顯示器的 特性的些微改變來做校正,讓品質維持ㄧ致的穩定性。
---------------------------------------------------------------------------------
有那些是螢幕QC的標準?
■ AAPM TG18
“Assessment of
Display
Performance for
Medical Systems”
A standard
established by
task group (TG)
18 of the
American
Association of
Physicists in
Medicine (AAPM).
■ DIN V
6868-57
“Image Quality
Assurance in
X-Ray Diagnosis
- Part 57”
established by
the Deutsches
Institut fur
Normung e.V.
(DIN). In line
with the QS-RL (Qualitatssicherungs-Richtlinie)
quality
assurance
ordinance, it is
mandatory in
Germany to refer
to this standard
when conducting
monitor quality
assurance.
■ PAS 1054
“Requirements
and Testing of
Digital
Mammography
Equipment”
established by
the
Normenausschusses
Radiologie (DIN
NAR) in
cooperation with
the Deutschen
Rontgengesellschaft
(DRG) and
others. In line
with the QS-RL (Qualitatssicherungs-Richtlinie)
quality
assurance
ordinance, it is
mandatory in
Germany to refer
to this standard
when conducting
monitor quality
assurance.
■ IEC
61223-2-5
“Evaluation and
Routine Testing
in Medical
Imaging
Departments -
Part 2-5”
established by
the
International
Electrotechnical
Commission (IEC).
■ IPEM Report
91
“Recommended
Standards for
the Routine
Performance
Testing of
Diagnostic X-Ray
Imaging Systems”
established by
the Institute of
Physics and
Engineering in
Medicine (IPEM).
■ JESRA
X-0093
“Quality
Assurance (QA)
Guideline for
Medical Imaging
Display Systems”
established by
the Japan
Industries
Association of
Radiological
Systems (JIRA)
in 2005.
■ ACR
“Practice
Guideline for
Determinants of
Image Quality in
Digital
Mammography”
A standard
established by
the American
College of
Radiology (ACR)
in cooperation
with the
American
Association of
Physicists in
Medicine (AAPM),
Radiological
Society of North
America (RSNA),
and Society for
Imaging
Informatics in
Medicine (SIIM).
■ EUREF
“European
Guidelines for
Quality
Assurance in
Breast Cancer
Screening and
Diagnosis”
A standard
issued by the
European
Commission in
cooperation with
the European
Reference
Organization for
Quality Assured
Breast Screening
and Diagnostic
Services (EUREF),
and European
Breast Cancer
Network (EBCN),
European Society
of Mastology (EUSOMA).
---------------------------------------------------------------------------------
那些軟體可以來校正螢幕的QC?
您需要一套軟體然後根據螢幕的特性定期得來校正它,確保螢幕的品質。